top of page
  • • Modular busbar trunking system, delivering maximum flexibility of power distribution and lighting supply
    • With hot-pluggable tap-offs, reconfigure your distribution in a matter of minutes
    • Adapt to evolutions of the building and of energy usage without powering off
    • Reduce the size and ground footprint of the power switchboards by decentralizing the protections into tap-offs located under ceilings
    • Suitable in all types of buildings

    Benefits of Canalis

    Standard compliance

    Certified and compliant with IEC 61439-6 standard by independent laboratories: ASEFA, LOVAG.

    Flexibility throughout the lifecycle

    Dedicated mechanical support systems ensure simplified Canalis installation and reduced installation time by up to 50%. Loads can be easily disconnected or added without halting the complete production, allowing a fast upgrade.

    Environment-friendly

    Green Premium labelled. Free of hazardous substances with well-documented end-to-end environmental impact. Electromagnetic radiations are minimized. Reconfiguration for reuse is possible.

    More functionalities

    Tap-off unit kits ensure safe monitoring of load distribution and equipment. These are also fully compatible with protection devices.

    Software tools: Make the most out of Canalis

    • CanBRASS
    • EcoStruxure Power Design - Ecodial
    • BIM busway : Canalis plug-in for Autodesk Revit
    • CanCAD : Canalis plug-in for AutoCAD

    Features: Canalis KN

    General specifications

    • Power distribution: triple-phase + neutral + protective earth
    • Max operational voltage or rated insulation voltage: 500 V AC
    • Degree of protection (IEC 60529): IP55, IK08
    • Coating: pre-lacquered white RAL 9001

    Line components

    • Current rating (Inc): 40, 63, 100 or 160 A
    • Rated permissible peak current (Ipk): 6, 11, 14 or 20 kÂ
    • Length of line components: 2 or 3 meters

    Tap-off units (outputs)

    - Inter-distance: 0.5, 1, or 1.5 meter
    - Hot-pluggable
    - Rated current: 16 to 63 A, Single-phase or triple-phase
    - Made to host Acti9 circuit-breakers

    Standards

    • Compliant with IEC61439-1 and -6, certified by ASEFA, LOVAG
    • Certified for application in marine environments by:
        • American Bureau of Shipping
        • Bureau Veritas
        • Det Norske Veritas
        • Lloyd’s Register of Shipping
        • Registro Italiano Navale e Aeronautico

    Canalis KN

      No hay reseñas todavíaComparte tu opinión. Deja la primera reseña.
      • Whatsapp
      bottom of page